• JSA template · ground-floor wet area
Tiling JSA template Australia
Ground-floor ensuite tiling is a JSA job when there is no fall greater than 2 m and no other high-risk construction work. Porcelain, silica, epoxy grout and a waterproofing certificate are the real hazards. The Leichhardt blog excerpt is a different bathroom on a different site — don’t clone it.
Not the Leichhardt bathroom
The SWMS vs JSA guide uses a ground-floor bathroom tile job in Leichhardt NSW next to a first-floor roof. This page is a new-house ensuite in Ballajura, WA: porcelain, epoxy grout, a waterproofing cert to honour, wet saw on the driveway. Same trade, different ground.
If this house also gets a metal roof this week, that roof is a roofing SWMS. Don’t stretch this JSA to cover it.
Filled example: ensuite, Ballajura WA
New dwelling, ground-floor ensuite only. Large-format porcelain, floor fall to a linear waste, epoxy grout in the shower. Waterproofing already certified. Saw on the driveway, not in a backyard like Leichhardt.
Example layout. Not the Leichhardt excerpt. A JSA is not a legal substitute for a SWMS on HRCW — if this site grows a roof crew, they need their own roofing SWMS.
| Step | Hazards | Controls | 5×5 risk |
|---|---|---|---|
1. Check the waterproofing certificate and protect the hallway Responsible: Leading hand |
|
| InitialL3×C3 = 9 Medium ResidualL1×C3 = 3 Low |
2. Cut porcelain on a wet saw on the driveway Responsible: Tiler |
|
| InitialL4×C4 = 16 Critical ResidualL2×C3 = 6 Medium |
3. Lay floor with fall to the linear waste, then walls Responsible: Tiler |
|
| InitialL3×C3 = 9 Medium ResidualL2×C2 = 4 Low |
4. Epoxy grout the shower, clean, leave for the plumber’s mixers Responsible: Tiler |
|
| InitialL3×C3 = 9 Medium ResidualL2×C2 = 4 Low |
Frequently asked questions
Do tilers need a JSA template?
For ground-floor wet areas that are not HRCW, yes — principals usually want a JSA. Silica from porcelain, wet-saw electrics and kneeling are enough reason to write it down. A roof on the same site still needs its own SWMS.
Is there a free tiling JSA?
Trial generate and PDF, no card. This Ballajura ensuite is not the Leichhardt tiling excerpt and not a document you sign for a high-rise.
SWMS or JSA for tiling?
Ground-floor ensuite: JSA. Scaffold on a facade, a fall over 2 m, or ACM in old adhesive: SWMS for that work. A JSA is not a legal substitute on HRCW.
Does a WA tiling JSA count in NSW or VIC?
Generate for the state you are standing in. WA and NSW use WHS; Victoria uses the OHS Act 2004 and OHS Regulations 2017. The JSA format is still not prescribed — site-specific steps are.
Generate a tiling JSA for this wet area
Falls to waste, cuts, state. Free trial, no credit card.