Electrical JSA template Australia (isolated fit-off)
An isolated, proved-dead fit-off of GPOs and lights — extra-low-risk, board locked off — can be a JSA. Work on or near energised installations cannot. If the adjacent board is live, or you cannot prove dead, use the electrical SWMS. Don’t split the difference on paper.
Isolated fit-off vs live work
This JSA assumes the DB for this tenancy is locked off, tagged, and proved dead, and you will not work in reach of remaining live parts. The café switchboard with an adjacent live tenancy is the electrical SWMS.
- Isolated GPO and light fit-off in a new office: this page.
- Fault-finding on a live board, or a shared cupboard with live bus: SWMS.
- Rooftop PV DC in daylight: solar SWMS, not this JSA.
Filled example: office fit-off, Nundah QLD
New ground-floor office. Board for this tenancy isolated by the builder’s sparkie of record. Clip, terminate GPOs, hang lights from a platform under 2 m, IR test. Energising the board later is a separate, SWMS-aware step — not hidden in this JSA.
Example layout. If you cannot prove dead, or live parts remain in reach, this JSA is the wrong document — use the electrical SWMS.
| Step | Hazards | Controls | 5×5 risk |
|---|---|---|---|
1. Confirm isolation, lock-out, prove dead on the conductors you will terminate Responsible: Licensed electrician |
|
| InitialL3×C5 = 15 High ResidualL2×C5 = 10 High |
2. Pull and clip cables, terminate GPOs on the isolated circuits Responsible: Electrician |
|
| InitialL3×C3 = 9 Medium ResidualL2×C2 = 4 Low |
3. Hang lights from a platform under 2 m Responsible: Electrician |
|
| InitialL3×C3 = 9 Medium ResidualL2×C2 = 4 Low |
4. Insulation resistance test; leave the board locked until the energise procedure Responsible: Licensed electrician |
|
| InitialL3×C4 = 12 High ResidualL2×C3 = 6 Medium |
Frequently asked questions
When is an electrical JSA template enough?
When the installation you will touch is isolated, locked out, and proved dead, and the remaining work is extra-low-risk fit-off — GPOs, lights, clipping — with no live parts in reach. That is not a licence to skip isolation.
Is the electrical JSA free?
Trial generate and PDF, no card. This Nundah office fit-off is a layout. A live café board is the other page.
SWMS or JSA for electrical work?
On or near energised installations: SWMS (HRCW). Isolated extra-low-risk fit-off: JSA. If you are not sure it is isolated, it is not a JSA job.
NSW, VIC, QLD, WA?
Licensing is state-based. Citations: WHS, or Victoria’s OHS Act 2004 and OHS Regulations 2017. The JSA does not replace an electrical licence.
What about livening at the end?
Closing a main onto a new circuit next to a live bus is often back in SWMS territory. Keep this JSA for the isolated fit-off; write the electrical SWMS for the energised part.